RX II Series User Manual
The Control Panel 3-10
Set
Communication
To build up the communication between host computer and
cutter.
Baud Rate
is to determine the speed of data transmission.
Data Bits
refers to the size of one block of data.
Parity
is used to check if data was revived correctly or not.
9600, n, 7, 1, p
9600pbs, 7 Bits with NO Parity
9600, o, 7, 1, p
9600pbs, 7 Bits with ODD Parity
9600, e, 7, 1, p
9600pbs, 7 Bits with EVEN Parity
9600, n, 8, 1, p
9600pbs, 8 Bits with NO Parity
9600, o, 8, 1, p
9600pbs, 8 Bits with ODD Parity
9600, e, 8, 1, p
9600pbs, 8 Bits with EVEN Parity
19200, n, 7, 1, p
19200pbs, 7 Bits with NO Parity
19200, o, 7, 1, p
19200pbs, 7 Bits with ODD Parity
19200, e, 7, 1, p
19200pbs, 7 Bits with EVEN Parity
19200, n, 8, 1, p
19200pbs, 8 Bits with NO Parity
19200, o, 8, 1, p
19200pbs, 8 Bits with ODD Parity
19200, e, 8, 1, p
19200pbs, 8 Bits with EVEN Parity
Firmware
Version
To display the version number of Firmware and FPGA code,
varying from model to model
Sizing Setting
Allows user to set the sizing settings.
If set to user defined mode, the user will be asked to select the
size setting every time the machine is turned on.
If set to Default Edge or Roll, Edge or Roll type sizing will be
performed whenever the machine is turned on.
User Defined,
Default EDGE,
Default ROLL
User Defined
Select
Language
To select displayed languages on LCM panel in English,
Spanish, Italian, Deutsch, Japanese, Portuguese, Polish,
Turkish or French.
English
Select Units
Provide four-unit systems for users convenient.
cm/s; inch/oz;
cm/oz; inch/gram
Metric
Scale Length
Fixed scaling, for maintenance only.
Scale Width
Image Scaling
Length
To adjust the image scale of media length and width that may
cause by the thickness of the media.
The Numerator is the ideal length, and the Denominator is
the actual length measured from the resultant.
For example, cutting a line with 500.0 mm length. The
procedure as follows:
1. Press the [LEFT ARROW] to choose the Numerator and
select 500.0 mm,
2. Cut the length by sending a graph file,
3. Measure the length then use the [RIGHT ARROW] key to
choose the Denominator, then
4. Press [UP ARROW /DOWN ARROW] to change the
values of the actual length.
Image Scaling
Width
DHCP
Shows your IP address for TCP/IP Configuration
Disable
IP Address
Shows the IP Address of your cutting plotter.
MAC Address
Shows the MAC Address of your cutting plotter.
Die/Kiss Cut
To perform die cut/kiss cut in one cutting line simultaneously
by designating the outline to green color RGB 255 and
defining the length and force setting on control panel (Please
refer to Chapter 4.9 for details).
Length: 0.2 ~9mm
Force: 45 g~ 450 g
Section Cut
To divides the long plot data into sectional output jobs to gain
higher cutting quality and increase precision.
Users can set the section by registration marks or input the
value manually.
Summary of Contents for RX II Series
Page 1: ...V 24 2020 May RX II Series User Manual http www GCCworld com...
Page 174: ...RX II User Manual GreatCut Plug In A 6 Step 5 Press the button on the right of Jog marks...
Page 190: ...RX II User Manual GreatCut Plug In A 6 Step 11 Go to GreatCut window press Output button...
Page 191: ...RX II User Manual GreatCut Plug In A 6...
Page 205: ...RXII User Manual SignPal 12 Instruction A 6...