Operations
Page 5 - 2
Orca III/ Orca III T Operation and Maintenance Manual
© GBC Films Group February 2001
5.2 Front control panel
The control panel on the Orca III/ Orca III T
Laminator is located at the front operating position of
the machine on the left ( control ) side cabinet.
The front control panel enables the operator
to control linear footage/ rate display, motor speed,
motor direction, motor auto/ stop, top temperature,
bottom temperature, main roller pressure and main
roller up/ down.
( 1 ) Speed Readout: Displays the speed of the
machine and the linear footage total. When the “ R” is
displayed, the readout is displaying the rate. When only
a numeric value is displayed, the readout is displaying
linear footage.
• The “ SEL “ button will toggle the unit between the
two choices of readouts. ( speed rate or linear
footage total )
• The “ RST “ button will reset the linear footage total
whether the display is showing rate or linear footage
total.
R 0.0
S E L
R S T
( 2 )Speed Control Dial: Adjusts the speed of the
motor from zero to a maximum speed of 15 feet per
minute ( 4.5 meters per minute ). Turn the dial
clockwise to increase speed and counter clockwise to
reduce speed.
FW D
R E V
A U T O
S T O P
S P E E D
( 3 )Forward / Reverse Switch: determines the motor
direction. In the FWD position, the motor will turn in
a forward motion. In the REV position, the motor
will turn in a reverse direction. In the center position,
the motor will not turn at all.
F W D
R E V
AU TO
STO P
SPEED
T he center position is to prevent jam m ing
of the m otor w hen changing directions
IN F O R M A T IO N
( 4 ) Auto / Stop Switch: This switch will engage the
motor circuitry and disengage the motor circuitry. This
is a momentary switch for latching purposes so that
two separate switches can serve the same function.
See Rear Control Panel for the other location of this
switch.
FW D
R EV
A U T O
S T O P
SPEED