![Garudan GPS/F-1006 Series User Programming Manual Download Page 67](http://html1.mh-extra.com/html/garudan/gps-f-1006-series/gps-f-1006-series_user-programming-manual_3692315067.webp)
Correction of Pattern
63
If the pointed point is the final needle entry point or the needle entry point except the top point, this operation will
be denied.
①
Selection of Relative Top Point Deletion
In the interface of code list, select the relative top
point deletion (Code 072)
to activate
the confirmation interface of the relative top point.
②
Performance of Relative Top Point Deletion
In the confirmation interface of relative top point,
press ENTER Key A to perform the relative top
point deletion, then the system returns to the
standard interface
When deleting relative top point, the whole pattern
data after the deleted point moves while holding the
previous relation before deletion.
In case of deleting the absolute top point: in the
interface of code list, select and perform the absolute
top point deletion (code 077)
. At this
time the pattern data after deleted point keep still.
Attention:
The result of point deletion may exceed the
sewing range as a part of the completed
pattern data. So, at this time, please use the
correction function to modify the pattern data
to the sewing range.
(2) Top Point Move (073
、
078)
Move the pointed needle entry point. Depending on whether the pattern data after the point move keep still, the
methods of top point move are divided into two methods: Relative Top Point Move and Absolution Top Point
Move.
Relative Top Point Move:The pointed point cannot be moved at the needle entry point other than top point.
Absolution Top Point Move:If the pointed point is the final needle entry point or the needle entry point other than
the top point, this operation will be denied.