Input of Pattern
49
①
Select Upper Thread Tension Setting
In the interface of code list, select upper thread
tension setting (Code 014)
to
activate the right interface.
②
Set Value for Upper Thread Tension
In the right interface, set the upper thread tension
value by pressing number keys or
+
/
-
keys.
After
is pressed, the set upper thread tension
value is inputted and the system returns to the
standard interface.
The value actually inputted as order:
Upper thread tension (No.014) =
Upper thread tension basic value (No.113) + the
inputted value (Adjusted value).
If the basic value of the upper thread tension
(No.113) is at
「
50
」
, and the upper thread tension
(No.014) is at
「
100
」
, the inputted value (adjusted
value) is
「
50
」
.
(11) Setting of Intermediate Presser Height (018)
Set the intermediate presser height. This value will be kept valid until there is a position for the next intermediate
presser height setting order.