190-00709-04 Rev. A
Garmin G1000 Pilot’s Guide for the Socata TBM 850
623
APPENDIX A
GMA 1347D MESSAGE ADVISORIES
Message
Comments
GMA1 FAIL
– GMA1 is inoperative.
The audio panel self-test has detected a failure. The audio panel is unavailable. The
G1000 system should be serviced.
GMA2 FAIL
– GMA2 is inoperative.
GMA XTALK
– GMA crosstalk error
has occurred.
An error has occurred in transferring data between the two GMAs. The G1000 system
should be serviced.
GMA1 CONFIG
– GMA1 config error.
Config service req’d.
The audio panel configuration settings do not match backup configuration memory.
The G1000 system should be serviced.
GMA2 CONFIG
– GMA2 config error.
Config service req’d.
MANIFEST
– GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed. The G1000 system should be serviced.
MANIFEST
– GMA2 software
mismatch, communication halted.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in the unit. Certain audio functions may
still be available, and the audio panel may still be usable. The G1000 system should be
serviced when possible.
GMA2 SERVICE
– GMA2 needs
service. Return unit for repair.
GIA 63W MESSAGE ADVISORIES
Message
Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio configuration. The G1000 system
should be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
COM1 CONFIG
– COM1 config error.
Config service req’d.
The COM1 and/or COM2 configuration settings do not match backup configuration
memory. The system should be serviced.
COM2 CONFIG
– COM2 config error.
Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000 system
should be serviced.
GIA2 COOLING
– GIA2 over
temperature.