190-00820-11 Rev. A
Pilot’s Guide for the Cirrus SR2x with Cirrus Perspective by Garmin
605
ADDITIONAL FEATURES
SY
STEM
O
VER
VIEW
FLIGHT
INSTRUMENTS
EIS
AUDIO P
ANEL
& CNS
FLIGHT
MANA
GEMENT
HAZARD
AV
OID
ANCE
AFCS
ADDITIONAL
FEA
TURES
APPENDICES
INDEX
FLITECHARTS CYCLE NUMBER AND EXPIRATION DATE
FliteCharts data is revised every 28 days. Charts are still viewable during a period that extends from the cycle
expiration date to the disables date. FliteCharts is disabled 180 days after the expiration date and are no longer
available for viewing upon reaching the disables date. When turning on the system, the Power-up Page displays
the current status of the FliteCharts database. See the table below for the various FliteCharts Power-up Page
displays and the definition of each.
Figure 8-75 Power-up Page, FliteCharts Database
FliteCharts Database
Power-up Page Display
Definition
Blank Line. system is not configured for FliteCharts. Contact a Garmin-
authorized service center for configuration.
System is configured for FliteCharts but no chart database is installed.
Refer to Updating Garmin Databases in Appendix B for the FliteCharts
database
Normal operation. FliteCharts database is valid and within current
cycle.
FliteCharts database is beyond the expiration date, but still within the
180 day viewing period.
FliteCharts database has timed out. Database is beyond 180 days
after expiration date. FliteCharts database is no longer available for
viewing.
Table 8-3 FliteCharts Power-up Page Annunciations and Definitions
When the 180 day grace period has expired, ‘Chart data is disabled.’ in yellow indicates the FliteCharts
database has expired and is no longer viewable. ‘Chart Data: N/A’ appears in white if no FliteCharts data is
available on the database card or no database card is inserted.
FliteCharts time critical information can also be found on the AUX - System Status page. The FliteCharts
database REGION, CYCLE number, EFFECTIVE, EXPIRES, and DISABLES dates of the subscription appear in