USER GUIDE
EdgeSafe Bypass | M100G1xx
8.4.3.21 bypass segment <select from list> rx-tx-errors net-op-mode <linkdrop|none>
Configure the mode to go into when errors per second on any Net ports exceed threshold for a bypass
segment.
Parameters:
segment: The segment to configure
linkdrop: Link is disabled when the appliance fails
none: Do nothing
8.4.3.22 bypass segment <select from list> rx-tx-errors rate-threshold <threshold >0>
Configure the threshold of errors per second for a bypass segment
Parameters:
segment: The segment to configure
8.4.3.23 bypass segment <select from list> rx-tx-errors trap <disable|enable>
Enable or disable bypass trap
Parameters:
segment: The segment to configure
disable: Disable trap
enable: Enable trap
8.4.3.24 bypass segment <select from list> rx-tx-errors timeout <>0 msec>
Configure the minimal time between traps for a bypass segment
Parameters:
segment: The segment to configure
8.4.3.25 clear bypass stats all
Clear all bypass statistics
8.4.3.26 clear bypass stats module <select from list>
Clear bypass statistics for a module
8.4.3.27 clear bypass stats segment <select from list>
Clear bypass statistics for a segment
8.4.3.28 clear bypass stats port <select from list>
Clear bypass statistics for a port
8.4.3.29 clear bypass error rxtx all
Clear all bypass RX/TX errors
8.4.3.30 clear bypass error rxtx module <select from list>
Garland Technology | 716.242.8500 | garlandtechnology.com/support
Copyright © 2021 Garland Technology, LLC. All rights reserved.
39