USER GUIDE
EdgeSafe Bypass | M100G1xx
8.4.3.6 bypass segment <select from list> hb active-expired-op-mode
<bypass|linkdrop|tap|tapa|tapai1|tapai2|tapai12|tapi12>
Configure heartbeat active expired operation mode for a bypass segment (the mode to go into when
heartbeat checking expires)
Parameters:
segment: The segment to configure
bypass: Bypass mode
linkdrop: Link is disabled when the appliance fails
tap: TAP mode (directional monitoring)
tapa: Aggregate mode (combined monitoring)
tapai1: Aggregate mode with dual injection from mon0
tapai2: Aggregate mode with dual injection from mon1
tapai12: Aggregate mode with dual injection from mon0 and mon1
tapi12: TAP mode with injection
8.4.3.7 bypass segment <select from list> hb fail-detect <uni|bi>
Configure heartbeat failure detection for a bypass segment
Parameters:
segment: The segment to configure
uni: Detect unidirectional heartbeat failure
bi: Detect bidirectional heartbeat failure
8.4.3.8 bypass segment <select from list> hb recover-time <0~50000 msec>
Configure the time to recover from a heartbeat-lost event for a bypass segment
Parameters:
segment: The segment to configure
8.4.3.9 bypass segment <select from list> hb hold-time <10~50000 msec>
Configure the time to hold received heartbeats for a bypass segment
Parameters:
segment: The segment to configure
8.4.3.10 bypass segment <select from list> hb interval <3~10000 msec>
Configure the heartbeat interval for a bypass segment
Parameters:
segment: The segment to configure