background image

Quick Reference Guide

WAV252 Heated Wind Vane

Installation and Maintenance

0002-028

www.vaisala.com

INSTALLATION

Initial Check

Prior to the installation check that the WAV252 is not
damaged during transportation. Check also that the shaft
rotates smoothly without any detectable noise. It is
recommended to mount the sensor body when the vane
assembly is removed. Be careful not to cause damage to the
shaft of the sensor body or to the connector pins.

Mechanical

The Heated Wind Vane WAV252 is preferably installed into
the WAC151 sensor cross arm. On bottom of the WAV252
there is a special button-shaped temperature sensor
(diameter 22 mm), elastically attached to the bottom plate.
This is for sensing the ambient temperature and should
therefore be set in good thermal contact with the mounting
support.

NOTE

  The three mounting screws properly tightened

will force the temperature sensor button firmly
enough against the support.

0002-024

Figure 1. Mounting of the Wind Sensor and the Hub

When installed to the WAC151 cross arm, the WAV252 is
mounted at the northern end, the southern end is reserved
for the WAA252 Heated Anemometer.

1.

First pre-assemble the three mounting screws, with
plastic washers, to the anemometer's mounting legs.

2.

Fit the 10-pin cable plug through the mounting flange
and connect it to the sensor.

3.

Mount the sensor to the flange by twisting, and tighten
the screws.

4.

Finally, mount the cup assembly. Align the planes in
the shaft and inside the hub. The bottom edges of the
hub and the shoulder should reach approximately the
same level (see Figure 1). Tighten the set screw.

WAC151 Wiring

The wiring diagram for the WA252 system to the WAC151
Sensor Crossarm is presented in the Figure 2. The power
input wire connections are highlighted, since they differ from
those for regular wind sensors.

0002-025

Figure 2. WAC151 Standard Wiring for WAA252 and WAV252

When using standard power and signal cables ZZ45049 and
ZZ45048 the connections are following:

1.

For power supply, connect the YEL, GRN, and PNK
colored wires to the screw terminal #2 and the WHT,
BRN, and GRY colored wires to the terminal #3.

2.

For signal output connect wires GRN, YEL, WHT, VIO,
GRY, and PNK to terminals #7 … #12. For signal
grounding, connect BLK to the terminal #5.

3.

For the optional sensor power input connect BRN to
the terminal #6.

As a power source use the Vaisala WHP25 Mains Power
Supply, which has a mast mountable, all-weather enclosure.