background image

Document #: G_GO_OM_G2000DECKOVEN_4606130 – 12/20

Page 8

Top Trim Installation

The front of the top trim is formed as a channel. Open the 

upper oven door. Hold the top trim with the rear raised 

and slide its lower flange into position in the oven opening 

between the right and the left front columns. Lower the top 

trim into position over the oven top. The top trim does not 

require that it be bolted or fastened into position.

Ovens with Optional Light Feature

Important: This appliance must be electrically grounded in 

accordance with local codes, or in the absence of local codes, 

the Canadian Electrical Code C22.1 or with the National 

electrical code ANSI/NFPA No. 70 (latest edition whichever is 

applicable.

Warning – Electric Grounding Instructions

This appliance is equipped with a three prong (grounding) 

plug for your protection against shock hazard and must be 

plugged into a properly grounded three prong receptacle. 

Do not cut or remove the grounding prong from this plug.

A wiring diagram is attached to the back of the unit.

Gas Connection-Single & Multiple Ovens

Single Oven

Install the pressure regulator (supplied) with the outlet 

(arrowhead) connected to the tail pipe. The ¾” N.P.T. inlet of 

the pressure regulator must be considered in piping the gas 

supply. Each group of ovens should be supplied (by others) 

with an in-line manual shut off valve.

INSTALLATION Continued

 

The flue deflector provided (Fig. 1) should be installed 

to prevent this situation from occurring. Set the flue 

deflector in place over the flanges of the internal flue. The 

sloped opening of the flue deflector will be to the front. 

Fasten the side flanges of the flue deflector by means of 

the sheet metal screws provided.

2.   If the oven must be connected to a direct flue, this flue 

should rise 10 feet above the roof of the building in 

which the oven is installed, or 10 feet above any portion 

of a building within a horizontal distance of 10 feet. The 

draft hood provided must be installed. In addition, it is 

necessary that barometric draft control (available from 

Garland) be installed. (See Fig. 2)

The draft hood should be positioned with its vertical bottom 

opening over the vertical flanges of the oven flue. The 

flanges of the draft hood should be to the sides and front. 

Fasten the draft hood to the oven by means of sheet metal 

screws through the holes on each side flange at the bottom 

of the draft hood.

The barometric damper must be installed to conform with 

the applicable instructions packed with the barometric 

damper. The relief opening of the barometric damper should 

be located so that it is not obstructed by any part of the oven 

or adjacent constructions.

The barometric damper should be installed as close to 

the draft hood as possible, while conforming to code 

requirements.

Under no circumstances should a flue pipe with less than 

a 6 inch diameter be installed between the oven and the 

chimney termination.

If more than one appliance is connected to a single vent, the 

vent shall be sized in accordance with sound engineering 

principles.

Summary of Contents for G2000

Page 1: ...without notice FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERV...

Page 2: ...nia to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborn...

Page 3: ...nces 6 Legs 7 Assembly of Two Section Oven 7 Installation of Oven Vent 7 Top Trim Installation 8 Ovens with Optional Light Feature 8 Gas Connection Single Multiple Ovens 8 Installation Of Oven Heat De...

Page 4: ...Document G_GO_OM_G2000DECKOVEN_4606130 12 20 Page 4 DIMENSIONS AND SPECIFICATIONS G2000 SERIES...

Page 5: ...hermostat controls burners to provide a 150 to 500 Fahrenheit temperature range affording a low temperature holding feature Each section is further provided with an independent ON OFF gas valve and 10...

Page 6: ...normal infiltration does not provide the necessary air outside air shall be introduced Clearances NOTE Unit must be installed with no less than 6 inches 152mm clearance from combustible construction...

Page 7: ...vidual manual shut off supplied by others during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSI 3 45 kPa NOTE Adequate clearance must be provided...

Page 8: ...be installed to prevent this situation from occurring Set the flue deflector in place over the flanges of the internal flue The sloped opening of the flue deflector will be to the front Fasten the sid...

Page 9: ...down into the front channels INSTALLATION Continued The steel hearth is designed as a one piece welded assembly and will pass through the oven door opening The rear of the steel hearth assembly rests...

Page 10: ...should be burned off before the oven is used for the production of food The following burn off procedure will also serve to cure the oven hearth If the curing procedure is not followed there is a pote...

Page 11: ...ime requirements will be affected by specific recipes varying methods of food preparation quality of ingredients and personal preferences as well as numerous other factors Your own techniques coupled...

Page 12: ...50 185 35 40 Boston Shoulder 4 6 325 350 185 45 50 Leg Fresh Ham Whole Bone In 10 14 325 350 185 25 30 Whole Boneless 7 8 325 350 185 40 45 Half Bone In 5 7 325 350 185 40 45 PORK SMOKED Ham Uncooked...

Page 13: ...low Sheet 375 30 35 Min Angel Food 400 20 30 Min Devil s Food 350 20 30 Min COOKIES Sugar 375 15 Min Chocolate Chip 375 15 Min Butter 400 10 15 Min Macaroons 350 20 Min PIES Apple 400 425 50 60 Min Ch...

Page 14: ...d These stains can usually be removed by vigorous rubbing with a scouring powder paste Use only stainless steel wood or plastic tools if necessary to scrape off heavy deposits of grease and oil Do not...

Page 15: ...Document G_GO_OM_G2000DECKOVEN_4606130 12 20 Page 15 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...therm Crem Delfield fitkitchen Frymaster Garland Kolpak Lincoln Manitowoc Merco Merrychef and Multiplex Bringing innovation to the table welbilt com 2020 Welbilt Inc except where explicitly stated oth...

Page 17: ...land Convotherm Crem Delfield fitkitchen Frymaster Garland Kolpak Lincoln Manitowoc Merco Merrychef et Multiplex L innovation au service de la restauration welbilt com 2020 Welbilt Inc sauf indication...

Page 18: ...Num ro du document G_GO_OM_G2000DECKOVEN_4606130 12 2020 Page 15 PAGE INTENTIONNELLEMENT LAISS E EN BLANC...

Page 19: ...g n ralement tre limin es en frottant vigoureusement avec une p te r curer en poudre N utilisez que des ustensiles en acier inoxydable en bois ou en plastique si n cessaire pour enlever les d p ts imp...

Page 20: ...es 400 F 204 C 20 30 min G teau du diable 350 F 177 C 20 30 min BISCUITS Au sucre 375 F 191 C 15 min Aux p pites de chocolat 375 F 191 C 15 min Au beurre 400 F 204 C 10 15 min Macarons 350 F 177 C 20...

Page 21: ...85 F 85 C 45 50 99 110 Cuisse jambon frais Entier avec os 10 lb 14 lb 4 5 kg 6 4 kg 325 F 350 F 163 C 177 C 185 F 85 C 25 30 55 66 Entier d soss 7 lb 8 lb 3 2 kg 3 6 kg 325 F 350 F 163 C 177 C 185 F 8...

Page 22: ...propre tableau MORCEAU POIDS TEMP RATURE DU FOUR TEMP RATURE C UR MIN LB MIN KG B UF C te r tie 6 lb 8 lb 2 7 kg 3 6 kg 300 F 325 F 149 C 163 C 140 F 60 C saignant 23 25 51 55 C te r tie 7 c tes 20 lb...

Page 23: ...couvertes d une fine couche d huile protectrice Br lez la avant d utiliser le four pour cuire des aliments La proc dure de br lage ci dessous permet galement de s cher la sole du four Si vous n effect...

Page 24: ...re de la porte du four La partie arri re de la sole en acier repose sur les d flecteurs de chaleur situ s l int rieur de la corni re de support arri re Centrez la sole en acier dans le four Installez...

Page 25: ...r conduite INSTALLATION suite Pour viter que cela ne se produise installez le d flecteur du conduit d vacuation fourni fig 1 Placez le d flecteur sur les brides du conduit d vacuation interne L ouvert...

Page 26: ...ression du r seau des pressions gales ou inf rieures psi 3 45 kPa REMARQUE laissez un espace suffisant autour de l appareil afin d en assurer l entretien et le bon fonctionnement Pieds Soulevez la par...

Page 27: ...D gagements REMARQUE installez l appareil de sorte laisser un d gagement d au moins 6 152 mm de chaque c t et l arri re de celui ci par rapport tout mat riau inflammable Si aucun mat riau combustible...

Page 28: ...ip e d un thermostat r sistant robinet d tranglement et d clic qui commande les br leurs Gr ce cela les br leurs peuvent chauffer le four une temp rature comprise entre 150 F 65 C et 500 F 260 C et ma...

Page 29: ...1 72 65 Po 1651mm 73 Po 1854mm 15 Po 394mm 38 Po 965mm 55 Po 1410mm 6 Po 152mm 120 000 G2121 771 57 Po 1460mm 65 Po 1664mm 15 Po 394mm 38 Po 965mm 48 Po 1219mm 6 Po 152mm 90 000 G2122 71 70 Po 1778mm...

Page 30: ...n four double 7 Installation du syst me de ventilation du four 7 Installation de la garniture sup rieure 8 Fours dot s d un clairage en option 8 Raccords de gaz pour fours simples ou multiples 8 Insta...

Page 31: ...reprotoxiques CMR L utilisation et l entretien de l appareil risquent de vous exposer des particules de laine de verre ou de fibres c ramiques en suspension dans l air L inhalation de particules de la...

Page 32: ...s pr avis POUR VOTRE S CURIT NE STOCKEZ NI N UTILISEZ D ESSENCE OU AUTRES VAPEURS OU LIQUIDES INFLAMMABLES PROXIMIT DE TOUT APPAREIL AVERTISSEMENT L INSTALLATION LE R GLAGE L ALT RATION L ENTRETIEN OU...

Reviews: