![background image](http://html1.mh-extra.com/html/garland/edgesafe-m10g1acv2/edgesafe-m10g1acv2_user-manual_564700109.webp)
USER GUIDE
EdgeSafe 10G Modular Bypass | Firmware Rev Level: 0.3.3.2
8.4.1.2 Heartbeat active mode lock select box
When HB active mode lock is ON the state of heartbeat active mode preserve after
reboot or after power on events. When HB active mode lock is OFF the state of
heartbeat active mode is automatically set to ON after reboot or after power on.
8.4.1.3 Heartbeat active restore select box
When the HB active mode is ON the IBS will restore to Inline (Normal) state when the
heartbeat packets will be received from the Monitor port. When HB active mode is OFF
the IBS preserves its state and no heartbeat packets are generated.
The following actions should be taken to restore the normal operation:
●
Restore the external environment to normal work.
●
Set the active Bypass select box to inline
●
Set the HB active mode to on
8.4.1.4 Active bypass select box
When heartbeat active mode is set to OFF the IBS stops sending the heartbeats and
the Active Bypass circuitry can be controlled manually by the Active bypass select box
to one of the following modes:Normal (Inline), Active Bypass, TAP, TAPI12, TAPA,
TAPAI1, TAPAI2, TAPAI12 or Linkdrop mode.
8.4.1.5 HB active expire select box
When heartbeat active mode is ON the IBS send heartbeat packets on its monitor
ports. If the IBS does not detect the heartbeat packet received from the monitor ports
the IBS will switch to Active Bypass or TAP, TAP, TAPI12, TAPA, TAPAI1, TAPAI2,
TAPAI12 or Linkdrop mode according to the predefined settings of the HB active
expire select box.
8.4.1.6 Device power off state select box
The IBS supports Disconnect or Bypass mode at power off. When in Disconnect, in any
event of power off the IBS will be in Disconnect mode - simulates switch / router cable
disconnection on the two network ports. When in Bypass, in any event of power off the
IBS will be in bypass mode. Pwoff_status is set to Bypass mode by default Bypass.
Supported only with new HW devices (IBSP hardware version 0.3.2.0 and up).
8.4.1.7 Heartbeat interval textbox
The IBS generates a heartbeat packet to monitor PORT0 every “hb_interval” msec.
(default - 5, min - 3,max - 10000). Heartbeat interval should be at least 3 times less
than heartbeat hold time.
Garland Technology | 716.242.8500 |