Control panel and display
Gardner Denver
12
3.7
Status messages table
Status messages table
Fault Xnnn: <Fault text>
A fault has been detected and the machine has shut down. See the compressor's “Fault History” for
more details (X=”F”, “E” or “A”; nnn = fault number)
Ready to start
The compressor is ready to start.
Motor starting…
The motor is currently starting.
Stopping procedure “x” s
The Soft Stop procedure is currently running and will complete in “x” seconds.
On-Load “x” rpm (min)
The compressor is On-Load (“min” denotes motor is currently running at allowed minimum rotational
speed).
On-Load “x” rpm
The compressor is running On-Load at “x” rpm.
On-Load “x” rpm (max)
The compressor is On-Load (“max” denotes motor is currently running at allowed maximum rotational
speed).
On-Load
The compressor is running On-load.
Off-Load “xxx” rpm
The compressor is currently Off-Load in continuous operation at allowed minimum rotational speed.
Off-Load
The Compressor is currently running Off-Load in continuous operation.
Off-Load Run-On Time
“x” s
The Run-On Timer has been activated and the compressor will switch to stand-by mode in “x”
seconds.
Off-Load “xxx” rpm
Run-On Time “x” s
The Run-On Timer has been activated and the compressor will switch to stand-by mode in “x”
seconds.
Attention: Start by Remote
Control…
Attention: This Compressor can start up at any time via remote control.
Attention: Start with Timer
Control on <Day of the Week> at
<Time>
Attention: The compressor will automatically start via the timer control at the week day and time
shown.
Attention: Start on ?? at <??:??> This message (including all the “????”) will appear if there is no valid timer schedule programmed (all
8 channels are Off). This means the compressor will never start. Check the settings in the
Timer
Control
Menu.
Attention: Start with Pressure
Requirement…
Attention: This Compressor will automatically start up as soon as there is a pressure requirement on
the network.
Attention: Start after De-
Pressurise…
Attention: The compressor will automatically start up as soon as the internal pressure in the screw air
end has dropped below Start Protection value.
Attention: Starting in “x” s after
Power Loss…
Attention: This Compressor has experienced a power loss. It will automatically restart in “x” seconds
Attention: Starting in “x” min
after Dryer Pre-Run…
Attention: This Compressor will automatically start as soon as the Dryer Pre-run time has elapsed.
VSD Initialising…
The converter is initialised.
Sending Data to VSD
(x %)
Parameters are being sent to set up the converter.