4 - DIGITAL OVEN PROGRAMMING
WARNING!
- By pressing once the RECIPES key the oven exits the program-
ming mode and goes back to MANUAL cooking mode. The
CHAMBER display indicates the temperature of the cooking
chamber (TEMPERATURE icon flashing) and the TIME/HUMIDITY
display indicates the time value of the initial turning on (00:00)
(TIME icon is lit).
42
By pressing the START/STOP key once the cooking program is started.
If the position which the recipe was meant to be stored in was already
taken, the preceding recipe is lost.
Pressing the ON/OFF key, at any moment, turns the card OFF and the
unsaved settings are lost.
4.3.2 Setting a temperature value
Press the INCREASE or DECREASE key to set the temperature value
(temperature range that can be set: 30 °C to 260 °C).
A five seconds’ timeout or by pressing the P3 key (TIME), P6 (HUMIDI-
TY), P7 (STEPS), (with the exception of the ON/OFF key) confirms the
set value and goes back to indicating the current temperature in the
cooking chamber (TEMPERATURE icon flashing).
Once the value has been confirmed the display values are permanently
lit.
4.3.3
Setting a cooking time value
As described in chapter 2.2 SETTING A COOKING TIME VALUE in the co-
oking part in MANUAL mode.
4.3.4 Setting of STEAM
- In PROGRAM mode, if you press the STEAM key you can set the level
of the steam/humidification inside cooking chamber for each cooking
phase (OFF - 20% -40% -60% - 80% - 100%).
During program changes the values on the display keep blinking.
Press the STEAM key to confirm selected value.
Once value is confirmed, the HUMIDIFICATION display disappears
(HUMIDIFICATION icon turns off when OFF is chosen, it is red lit if a
value between 20% to 100% is chosen) and TIME display (CLOCK icon
red lit) appears on display.
Press the START/STOP key in order to start the cooking cycle, it also
starts the humidification cycles if the set values are from 20% to 100%
and the real temperature in the cooking chamber has exceeded 90 °C.
Humidity icon permanently red-lit only when humidification is active,
flashing (0.5 on - 0.5 off) to indicate the off time of the solenoid valve
cycle.
In case of change of rotation of the fan/ ‘reverse’ motors, the humidi-
fication is interrupted momentarily and then it is restarted automati-
cally.
EN