MMC Ethernet TCP/IP Option Mod-
ule
G & L Motion Control Inc.
MMC Hardware Manual
119
A typical MMC 10Base T connection is shown below.
Figure 6-3: Ethernet - TCP/IP 10Base T Connections
6.2.1
The Ethernet Port
The 10Base-T port uses a RJ-45 style 8-pin connector using 100
ohm unshielded twisted pair category 3 or 5 cable (IEEE 802.3
section 14.4). The maximum length of the twisted pair cable
segment is 100 M (328 ft). NOTE: The connector is also suitable
for shielded cable and will ground the shield to the chassis.
•
Pin descriptions for are provided in
•
Pin assignments are provided in
•
The available Ethernet Port to Ethernet Device cables are
described in
Node
Node
Node
Shielded 10Base T Twisted Pair
Maximum segment length is 100 M (328 ft).
Segment
1.
2.
MMC
COM2
10 BaseT
REMOTE
PROGRAMMER
ACCESS
Disable
Enable
COM2
COM1
OUT
IN
OUT
IN
COL
PREV
GDLNK EO EI
ETHERNET
COM1
DIAG
Hub
Summary of Contents for MMC-A2
Page 1: ...Standalone MMC TM Hardware Manual Version 15 0 G L Motion Control Inc...
Page 2: ......
Page 36: ...Installation Operation Maintenance 28 MMC Hardware Manual G L Motion Control Inc...
Page 124: ...Standalone Digital MMC Control 116 MMC Hardware Manual G L Motion Control Inc...
Page 136: ...MMC Ethernet TCP IP Option Module 128 MMC Hardware Manual G L Motion Control Inc...
Page 175: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 167...
Page 176: ...CE and EMC Guidelines 168 MMC Hardware Manual G L Motion Control Inc...
Page 177: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 169...
Page 178: ...CE and EMC Guidelines 170 MMC Hardware Manual G L Motion Control Inc...
Page 186: ...Appendix A Operation Details 178 MMC Hardware Manual G L Motion Control Inc...