The values received from the device will be stored in iButton[1].
Connecting DBG-S11D dosimeter via RS485
interface
DBG-S11D dosimeter is intended for continuous measuring ambient equivalent dose rate
(ADER). The tracker enables to receive the current ADER readings in 3V/h and data on
dosimeter state. Then this information will be sent to the server. One dosimeter operation is
supported. The dosimeter can be connected simultaneously with fuel sensors and Galileosky
photo camera.
The order of DBG-S11D dosimeter connection:
1.
Connect the RS485A, RS485B, GND contacts of the tracking device and the RS485A
(contact 1), RS485B (contacts 2), GND (contact 6) of the dosimeter correspondingly.
Dosimeter has separate power supply.
2.
Configure the RS485 port in the tracking device to operate with fuel level sensors, photo
cameras and dosimeter. It can be done by the RS485FN 2 command or in the
Configurator on Settings\Digital inputs tab.
3.
Specify dosimeter data in the transmission protocol to the server. If dosimeter data sending
is off, the tracker will not sample DBG-S11D.
Connecting PressurePro tires pressure monitoring
system
Can be applied only for modifications equipped with RS232 interface.
PressurePro tires pressure monitoring system enables to carry out continuous control of pressure
in tires and tire temperature and warns about critical situations. The system consists of wireless
pressure sensors, installed on tires, and monitor, receiving data from sensors. The tracking
device connects to PressurePro monitor via RS232 interface and receives data about sensors
state and measured parameters.
Connecting PressurePro:
1.
Connect RXD, TXD, GND contacts of the tracking device and TXD (white), RXD (green),
GND (black) contacts of monitor correspondingly. Monitor has separate power supply.
2.
Configure the RS232 port in the tracker to operate with PressurePro. It can be performed
by the RS2320 13 command or in the Configurator on Settings\Digital inputs tab.
3.
Specify PressurePro data in the transmission protocol to the server.
By default, PressurePro sensors transmit data once in 5 minutes or by emergency arising
(tripping sensors, pressure reduction and etc.). The tracker transmits PressurePro data to the
server by analogy: once in 5 minutes or by emergency arising, data are not transmitted at
passing points to save GPRS-traffic. Operation of up to 34 sensors is supported.