User Manual Galileosky Base Block
38
4.
Specify the parameters transferred to the server. HEADPACK OR MAINPACK commands
can also be used (section
Server exchange protocol settings
) or in the Configurator on
Settings/Track tab.
Connecting CUB5B indicator
Can be applied only for modifications equipped with RS232 interface.
The CUB5B indicator is a segment 8-bit indicator, which can be connected to the tracking
device using RS232 interface. It can display current sensors data, CAN-bus data, mileage
and
so on.
Information updates every second.
Connection:
1.
If the indicator was set to operate with other equipment, it is necessary to reset to factory
settings. If the indicator is new, it is unnecessary.
2.
Connect RXD, TXD, GND tracker contacts and TX, RX and Ground contacts of the CUB5B
correspondingly.
3.
Configure RS232 port in the tracking device for operation with indicator, it can be done
by RS2320 7 command or in the Configurator on Settings\Digital inputs tab.
4.
Choose the displayed parameter, it can be done by CUB5 command or in the
Configurator on Settings\Digital inputs tab.
Connecting CI5010A weight indicator
Can be applied only for modifications equipped with RS232 interface.
The CI-5010A weight indicator is designed to measure, control and indicate electrical signals
produced by weight measuring strain gages sensors. It can be connected to the tracking device
via RS232 interface.
The order of CI-5010A connection:
1.
Adjust the indicator to output the measured value constantly.
2.
Connect RXD, TXD, GND contacts of the tracker and TX, RX, Ground of CI-5010A
correspondingly.
3.
Configure the RS232 port in the tracking device to operate with the indicator. It can be
done by the RS2320 12 command or in the Configurator on Settings\Digital inputs tab.
4.
Set «RS232» tag for sending to the server;
5.
If possible, measured weight exceeds the interval [0, 65535], turn on the dynamic archive
and set «Extended RS232 data» tag sending.
The data from the indicator are rounded up to a whole number. Measured weight is transmitted
in two tags: «RS232» and «Extended RS232 data». If measured weight is within the interval
from 0 to 65535 kg, it is transmitted only in «RS232» tag, weight is calculated in a different
manner according to a formula «RS232»+65535x«Extended RS232 data». Signed number is
transmitted in «Extended RS232 data» tag, thus, it is possible to receive both positive and
negative weight.