User Manual Galileosky Base Block
40
«RS232»+65535
«Extended RS232 data». Signed number is transmitted in «Extended
RS232 data» tag, thus, it is possible to receive both positive and negative weight.
Connecting WIN SCALE weight indicator
Can be applied only for modifications equipped with RS232 interface.
The Dinamica Generale S.pA. WIN SCALE weight indicator is designed to measure, control
and indicate electrical signals produced by weight measuring strain gages sensors. It can be
connected to the tracking device via RS232 interface.
The order of WIN SCALE connection:
1.
Adjust the indicator to output the measured value constantly. Port speed is 9600 bit/s.
2.
Connect RXD1, TXD1, GND contacts of the tracking device and TX, RX, Ground of WIN
SCALE correspondingly.
3.
Configure the RS232 port in the tracking device to operate with the indicator. It can be
done by the RS2320 19 command or in the Configurator on Settings\Digital inputs tab.
The data from the indicator are rounded up to a whole number. By receiving the message about
the changed weight from the indicator, the tracker records a point and sends it to the server. If
measured weight is within the interval from 0 to 65535 kg, it is transmitted only in «RS232»
tag, weight is calculated in a different manner according to a formula
«RS232»+65535
«Extended RS232 data». Signed number is transmitted in «Extended
RS232 data» tag, thus, it is possible to receive both positive and negative weight.
Connecting devices operating via WIEGAND26
protocol
To connect the devices operating via WIEGAND26 protocol:
1.
Connect In0, In1, GND contacts of the tracking device with Data0, Data1, GND of the
device correspondingly.
2.
Set analog inputs of the tracking device for operation with device via WIEGAND26
protocol. It can be set by commands InCfg0 4, InCfg1 5 or in Configurator program, tab
“Settings”/”Digital inputs”.
The values received from the device will be stored in iButton[1]. Every 4 seconds the values will
reset.
Connecting Matrix 5 RFID-codes reader via
RS485 interface
The order of Matrix5 connection:
1.
Connect the RS485A, RS485B, GND contacts of the tracker and the RS485A, RS485B,
GND of the Matrix5 correspondingly.
2.
Configure the RS485 port in the tracking device to operate with the reader. It can be done
by the RS485FN 1 command or in the Configurator on Settings\Digital inputs tab.
3.
Reset the tracking device.