![Galil Motion Control DMC-42 0 Series User Manual Download Page 144](http://html1.mh-extra.com/html/galil-motion-control/dmc-42-0-series/dmc-42-0-series_user-manual_3267467144.webp)
8-Bit I/O Block
Block
Binary Representation
Decimal Value for Block
17-24
2
2
0
1
25-32
3
2
1
2
33-40
4
2
2
4
41-48
5
2
3
8
The simplest method for determining n:
Step 1.
Determine which 8-bit I/O blocks to be configured as outputs.
Step 2.
From the table, determine the decimal value for each I/O block to be set as an output.
Step 3.
Add up all of the values determined in step 2. This is the value to be used for n.
For example, if blocks 2 and 3 are to be outputs, then n is 3 and the command, CO3, should be issued.
NOTE
: This calculation is identical to the formula: n = n2 + 2*n3 + 4*n4 + 5*n5 where nx represents the block.
Saving the State of the Outputs in Non-Volatile Memory
The configuration of the extended I/O and the state of the outputs can be stored in the non-volatile flash memory
with the BN command. If no value has been set, the default of CO 0 is used (all blocks are inputs).
Accessing Extended I/O
When configured as an output, each I/O point may be defined with the SBn and CBn commands (where n=1
through 8 and 17 through 48). Outputs may also be defined with the conditional command, OBn (where n=1
through 8 and 17 through 48).
4080
For 5-8 axis controllers, each I/O point may be defined with the SBn and CBn commands (where n=1
through 48).
The command, OP, may also be used to set output bits, specified as blocks of data. The OP command accepts 3
parameters. The first parameter sets the values of the main output port of the controller (Outputs 1-8, block 0).
The additional parameters set the value of the extended I/O as outlined:
OP m,a,b
where m is the decimal representation of the bits 1-8 (values from 0 to 255) and a,b,c,d represent the extended I/O
in consecutive groups of 16 bits (values from 0 to 65535). Arguments which are given for I/O points which are
configured as inputs will be ignored. The following table describes the arguments used to set the state of outputs.
Argument
Blocks
Bits
Description
m
0
1-8
General Outputs
a
2,3
17-32
Extended I/O
b
4,5
33-48
Extended I/O
For example, if block 8 is configured as an output, the following command may be issued:
OP 7,,7
This command will set bits 1,2,3 (block 0) and bits 33,34,35 (block 4) to 1. Bits 4 through 8 and bits 36 through 48
will be set to 0. All other bits are unaffected.
When accessing I/O blocks configured as inputs, use the TIn command. The argument 'n' refers to the block to be
read (n=0,2,3 or 4). The value returned will be a decimal representation of the corresponding bits.
Individual bits can be queried using the @IN[n] function (where n=1 through 8 or 17 through 48). If the following
command is issued;
Individual bits can be queried using the @IN[n] function (where n=1 through 48).
Chapter 7 Application Programming ▫ 140
DMC-42x0 User Manual
Summary of Contents for DMC-42 0 Series
Page 195: ...ICM 2900 PCB Layout Appendices 191 DMC 42x0 User Manual...
Page 205: ...CB 50 100 Drawings Appendices 201 DMC 42x0 User Manual...
Page 206: ...Appendices 202 DMC 42x0 User Manual...
Page 207: ...Appendices 203 DMC 42x0 User Manual...
Page 208: ...Appendices 204 DMC 42x0 User Manual...
Page 209: ...Appendices 205 DMC 42x0 User Manual...
Page 210: ...Appendices 206 DMC 42x0 User Manual...
Page 211: ...Appendices 207 DMC 42x0 User Manual...
Page 214: ...CB 50 80 Drawing Appendices 210 DMC 42x0 User Manual...