BIOMETRIC READERS
GCS-HW-0117-SG-RDRWIR-QRG
Page 3 of 10
5.0
IDEMIA (Morpho) SIGMA Biometric Reader - Cable Specs & Wiring
•
3-conductor, 20 - 24 AWG, overall shielded; non-stranded; max cable distance is 500 feet.
•
2-conductor, 16 AWG for at +12vdc (18 AWG for +24vdc) for 500 feet distance. Reader draws 1A at 12v (0.5A at 24v).
•
Cat-5e Ethernet cable for TCP/IP communication back to the server; max cable distance 300 feet.
•
Separate power supply required (current draw is 1A). You must common the reader's power supply ground to controller ground.
•
Ground the drain-wire at one end only - land drain wire at the DRM Board (GND).
•
Refer to reader manufacturer’s instructions for wiring (manufacturer's specs may supersede Galaxy specs).
•
635-DRM Board (Dual Reader Module) – PN 20-0235-10
•
DRM Relay-2 is used to control Sigma “Wait for Panel Decision” for Voice/Prompt synchronization.
635-DRM Terminal Functions (PN 20-0235-10)
Wiegand Reader
LED
(LED control line)
D 1
(Data 1)
WIEG DATA 1
VDC
(+12 VDC)
( Do not use for reader power! )
VDC
(to separate power supply.)
GND
(common the reader p.s. ground to controller p.s. ground)
GND
(common to controller ground)
D 0
(Data 0)
WIEG DATA 0
635-DRM RELAY-2
SIGMA “Wait for Panel Decision”
COM
(must tie to ground of the reader’s power supply)
- -
NO
(for voice/prompt control line)
LED1
NOTES:
•
“Wait for Panel Decision”: connect Sigma LED1 to the ‘NO’ leg of Relay-2. The ‘COM’ leg of Relay-2 must be tied to DRM GND.
•
Set Relay-2 for Timed Mode (1 to 2 secs) and “Valid Unlock” checkbox must be "checked" in System Galaxy Reader
Properties.
6.0
Invixium (IXM) Biometric Reader - Cable Specs & Wiring
•
3-conductor, 22 AWG, overall shielded; non-stranded; max cable distance is 500 feet.
•
2-conductor, 18 AWG for at +12vdc for 500 feet distance. Reader draws 1A at 12v .
•
Cat-5e Ethernet cable for TCP/IP communication back to the server; max cable distance 300 feet.
•
Separate power supply required (current draw is 1A). Must common reader's p.s. ground to controller ground.
•
Ground the drain-wire at one end only - land drain wire at the DRM Board (GND).
•
Refer to reader manufacturer’s instructions for wiring (manufacturer's specs may supersede Galaxy specs).
•
635-DRM Board (Dual Reader Module) – PN 20-0235-10
•
635-DRM LED is used to control reader’s for Voice Command when configured for “Wait for Panel Decision”.
635-DRM Terminal Functions (PN 20-0235-10)
Invixium Reader
LED
(LED control line)
ACP LED1
(used to control Voice Command)
D 1
(Data 1)
W DATA_OUT1
VDC
(+12 VDC)
( Do not use for reader power! )
GND
(common ground; drain wire)
VIN
–
(GND)
(bond to controller GND)
D 0
(Data 0)
W DATA_OUT0
VIN + (VDC)
to separate power supply
VIN
–
(GND)
to separate power supply
NOTES:
•
The IXM Reader must be configured to “follow panel decision” in the IXM-WEB software in reader configuration screen.
•
Galaxy controller must be set for Door Lock = Steady-High; Door Unlock = Steady-Low in the
LED Options tab
of the
Loop/Cluster Properties
screen.