CompuScope 82GC
103
Single channel mode
In single channel mode, GCLK is always one-sixteenth the frequency of the sampling clock.
Consequently, Trigger Out signal will be activated after any one of the sixteen rising edges of the sampling clock
after the trigger latency has expired.
Figure 65: Trigger Out in single channel mode
Dual channel mode
In dual channel mode, GCLK is always one-eighth the frequency of the sampling clock.
Consequently, Trigger Out signal will be activated after any one of the eight subsequent rising edges of the
sampling clock after the trigger latency has expired.
Figure 66: Trigger Out in dual channel mode