Configuring G-SPEED Studio XL
G SPEED
STUDIO
XL
with Thunderbolt™
p. 82
Viewing Logical Drive Check Tables
This feature allows you to view error tables. Use this information to evaluate the integrity of a logical
drive and determine whether corrective action is needed.
To view logical drive check tables:
1. Do one of the following actions:
• Click the
Logical Drive
icon.
• From the Storage menu, choose
Logical Drive
. The list of logical drives will appear.
2. Mouse-over the logical drive you want, then click the
Check Table
button.
3. Choose an option:
•
All
– All errors (default)
•
Read Check
– Read errors for this logical drive
•
Write Check
– Write errors for this logical drive
•
Inconsistent Block
– Inconsistent blocks for this logical drive, meaning that mirror
data for RAID levels 1, 1E and 10 and/or parity data for RAID levels 5 and 6 may contain
errors. Inconsistencies are identified by the Redundancy Check.
The Check Table lists:
•
Table Type
– Read Check, Write Check or Inconsistent Block
•
Start Logical Block Address
– The LBA of the first block for this entry
•
Count
– The number of errors or continuous blocks starting from this LBA
4. Click the
X
icon to close the information panel.
To clear the check tables, see
Clearing Statistics
.
Creating a Logical Drive Manually
This feature creates a logical drive only. You can also use the Wizard to create a disk array with logical
drives and spare drives concurrently. See
Creating a Disk Array and Logical Drive With the Wizard
. To
create a logical drive manually: