1. RADAR OPERATION
1-33
1.19.3
VRM unit of measurement (B and C types)
1. Left-click the MENU box to open the menu.
2. Select 2 [MARK].
3. Select 9 [EBL, VRM, CURSOR SET] then push the scrollwheel.
4. Select VRM1 or VRM2 as appropriate and push the scrollwheel.
5. Select unit of measurement desired then push the scrollwheel.
6. Push the right button twice to close the menu.
1.19.4
TTG to VRM indication
You can show the TTG to VRMs as follows:
1. Left-click the MENU box to open the menu.
2. Select 9 [CUSTOMIZE·TEST] to open the CUSTOMIZE·TEST menu.
3. Select 7 [OPERATION].
4. Select 0 NEXT.
5. Select 3 VRM TTG.
6. Select OFF, 1, 2 or 1+2 as applicable and push the left button.
OFF: NO VRM TTG display
1:
TTG to VRM1
2:
TTG to VRM2
1+2: TTG to VRM1 and VRM2
7. Push the right button four times to close the menu.
VRM1
>3.682NM<
00:00
TTG indication
VRM and TTG indications