FURUNO
FAR-21x7/28x7 SERIES
SP - 3
E3519S01N-M
VDR, VHW, VTG, VWR, VWT, WPL, ZDA
4.5 Output data sentences ABM, ACK, ALR, BBM, OSD, RSD, TLB, TLL, TTD, TTM, VSD
5. POWER
SOURCE
5.1 Display
unit
MU-201CR
24 VDC:2.3 A or 100-230 VAC: 0.7 A, 1 phase, 50/60 Hz
MU-231CR
24 VDC:3.2 A or 100-230 VAC: 0.9 A, 1 phase, 50/60 Hz
MU-170C
12-24VDC: 6.0-3.0 A (-BB type)
5.2 Processor unit
24VDC or 100-115/220-230 VAC, 1 phase, 50/60 Hz
FAR-2117(-BB)/2817
24VDC: 7.6A (8.5A) or
100-115 VAC: 2.6A (3.0A), 220-230 VAC: 1.6A (1.7A)
FAR-2127(-BB)/2827 24 VDC: 8.8A (9.7A) or
100-115 VAC: 3.0A (3.4A), 220-230 VAC: 1.8A (1.9A)
( ): Value for 42 rpm antenna unit
FAR-2827W
100-115 VAC: 3.2A, 220-230 VAC: 1.6A
FAR- 2137S/2837S/2837SW 100-115 VAC: 3.0A, 220-230 VAC: 1.5A
5.3
Antenna unit
S-band: 200/220/380/440 VAC
, 3 phase, 50/60 Hz
Antenna voltage input (100 kn)
Model
200 VAC,
3ø, 50 Hz,
220 VAC,
3ø, 60 Hz
380 VAC,
3ø, 50 Hz,
440 VAC,
3ø, 60 Hz
220 VAC,
3ø, 50 Hz
(HSC)
220 VAC,
3ø, 60 Hz
(HSC)
440 VAC,
3ø, 60 Hz
(HSC)
FAR-2137S/2837S
3.0 A
1.5 A
3.5 A
3.5 A
1.7 A
FAR-2837SW
3.0 A
1.5 A
-
-
-
5.4
Console
115/230 VAC, 1 phase, 50/60 Hz
5.5
Transformer (
option)
For single phase:
RU-1803:
440 VAC, 1 phase, 50/60 Hz
For triple phase:
RU-5693: 110 VAC, 3 phase, 60 Hz
RU-6522: 220 VAC, 3 phase, 50 Hz
RU-5466-1: 440 VAC, 3 phase, 50 Hz
6. ENVIRONMENTAL
CONDITIONS
6.1 Ambient
temperature
Display/processor/transceiver/control/power supply unit
-15°C to +55°C
Antenna unit
-25°C to +55°C (s70°C)
6.2 Relative humidity
less than 95% at 40°C
6.3 Degree of protection
Display/processor/control/power supply unit
IPX0
Monitor unit (MU-170C) Front panel: IP56, Chassis: IP20
Antenna unit
IPX6
6.4 Vibration
IEC60945
Ed.4
7. COLOR
7.1 Display unit (MU-201/231CR) Chassis: 2.5GY5/1.5, Panel: N3.0 (fixed)
7.2 Monitor unit (MU-170C) N2.5 (fixed)
7.3 Processor unit/ Power supply unit
2.5GY5/1.5
7.4 Control unit
N3.0 (fixed)
7.5 Antenna unit
N9.5 (fixed)