1. RADAR OPERATION
1-89
[PRIMARY
ALARM]
1 BACK
2
TARGET ALARM
WATCH
ALARM
TT
NEW
TARGET
TT
LOST
TARGET
TT AUTO ACQ TGT FULL
TT
MAN
ACQ
TGT
FULL
AIS
NEW
TARGET
AIS
LOST
TARGET
AIS
TGT
FULL
XTE
ARRIVAL
WPT
DEPTH
ANCHOR
WATCH
NO CPA/TCPA FOR AIS
1.44.4 Primary
alarm
Violated alarms appear in the Alert Box in the order of priority shown in the table
below.
Priority Alarm
group
Alarms
1 Error
(sensor
and system)
Azimuth, Datum EPFS, Gyro, Headline, Key, Log, RF,
Trigger, TT System Error, Video
2
Primary
See the PRIMARY ALARM menu below. TT CPA LIMIT
and NO CPA/TCPA FOR AIS are ON in default.
3
Other alarms
Any alarm not listed here.
If desired you can assign primary alarms the same priority as Error alarms.
1. Left-click the MENU box to open the menu.
2. Select 3 [ALARM].
3. Select 0 [PRIMARY ALARM].
PRIMARY ALARM menu
4. Select alarm(s) for which you want to give priority equal to that of Error
alarms. Selected alarms are underlined.
5. Press the right button several times to close the menu.