FURUNO
FAR-21x7/28x7 SERIES
SP - 4
E3519S01N-M
8. PERFORMANCE
MONITOR
PM-31 (X-band)
Frequency range
9370 to 9450 MHz
Input power
+8dBm min., +28dBm max.
Output power
-36dBm (2
nd
pulse max. output), -56dBm (2
nd
pulse min. output)
Step levels
7.5 to 10.5dB (1
st
pulse to 2
nd
pulse)
PM-51 (S-band)
Frequency range
3020 to 3080 MHz
Input power
-5dBm min., +15dBm max.
Output power
-15dBm (2
nd
pulse max. output), -35dBm (2
nd
pulse min. output)
Step levels
9.0 to 11.0 dB (1
st
pulse to 2
nd
pulse)
9.
SWITCHING HUB HUB-100
9.1 Access
format
CSMA/CD
9.2 Switching format
Store and Forward
9.3 Transmission speed
Semi-duplex: 10 Mbps/100 Mbps, Full-duplex: 20 Mbps/200 Mbps
9.4 Cable category
10 BASE-T: Category 3 or higher STP cable
100 BASE-TX: Category 5 or higher STP cable
9.5 Maximum cable length 100 m
9.6 Number of ports
8 ports
9.7 Port functions
Auto-MDI/MDI-X compliant (straight/cross cable auto-recognition)
EMC compliant (STP cable port)
3 LED injectors (Link/Act, Full-duplex/Collision, 100/10 Mbps)
9.8 Environmental
conditions
Ambient temperature
-15 to +50°C
Relative humidity
95% (at 40°C)
EMC IEC
60945
Degree of protection
IPX0
9.9 Power source
100-230VAC: 0.1A or less
9.10 Coating color
N3.0