U
lstein Power & Control AS
This document and its content is the property of ULSTEIN. Non-
public information contained herein shall be treated as
Confidential Information. No use, copying, citation or publication
of this document or its content is permitted without prior written
consent from ULSTEIN. Any conflicts arising from unauthorized
use shall be governed by the laws of Norway.
File Name:
BRI-D32004-01II (D)
System Installation
Manual.doc
Page:
Page 24 of
56
3.4.4.
Network configuration of magicplex8
Figure 9: Network configuration
If you did not choose the “Manual configuration”, these field are enable and pre-filled with the
current information about the selected multiplexer. You can change here the IP address, the
default gateway and the hostname of the current multiplexer. By clicking “Change network
configuration” you will send this new network configuration to the multiplexer
NOTE: The network configuration is independent from the rest of configuration. All other
settings (Port configurations logging, etc) must be set by using the upload configuration function.
3.4.5.
Data validation
Data validation is done before trying to change the network configuration. If these controls fail,
then an information message is displayed and nothing happens.
The following controls take place:
-
The IP address must be of the form X.X.X.X where X are numbers between 0 and 255.
Additionnally, the first number must be between 1 and 223 (inclusive), and different from
127.
-
The netmask must be of the form X.X.X.X where X are numbers between 0 and 255. It
must respect the constraints of a netmask (i.e. as a binary representation, it must be a
continuous sequence of 1 followed by a continuous sequence of 0). 0.0.0.0 and
255.255.255.255 are forbidden.
-
The combination of the IP address and the netmask must make sense: the "host" part of
the IP address (not masked by the netmask) can not be 0.
-
The default gateway can be empty (no default gateway will be used), but if not, it must be
of the form X.X.X.X where X are numbers between 0 and 255. The first number can not
be 0.
-
The hostname can be any combination of small unaccentuated letters (a-z), capital
unaccentuated letters (AZ), numbers (0-9), dashes (-), underscores (_) and points (.). It
must contain between 1 and 32 characters (inclusive). This means for example that it can
not contain any space.
Summary of Contents for FA-150
Page 2: ...This page left intentionally blank ...
Page 4: ...This page left intentionally blank ...
Page 5: ...Revision history manual Rev A B C Description Date dd mm yyyy Sign A A 06 05 2015 HAB ...
Page 6: ...This page left intentionally blank ...
Page 8: ...This page left intentionally blank ...
Page 9: ...Index divider Section 1 N ...
Page 10: ......
Page 12: ...PRINTED IN JAPAN UAIS TRANSPONDER FA 150 ...
Page 53: ...Antenna Cable Set CP20 02700 004 381 160 CP20 02710 004 381 170 A 8 ...
Page 54: ...Antenna cable Set CP24 00300 000 041 938 CP24 00310 000 041 939 A 9 ...
Page 55: ...Y Hatai D 1 ...
Page 56: ...Y Hatai D 2 ...
Page 57: ...Y Hatai D 3 ...
Page 58: ...Y Hatai D 4 ...
Page 59: ...Feb 19 03 D 5 ...
Page 60: ...May 20 03 D 6 ...
Page 61: ...Feb 22 05 D 7 ...
Page 62: ...Jan 9 03 D 8 ...
Page 63: ...Mar 11 04 H Hayashi D 9 ...
Page 64: ...Feb 02 05 D 10 ...
Page 65: ...Nov 28 03 D 11 ...
Page 66: ...Oct 02 03 D 12 ...
Page 67: ...H Hayashi Mar 10 05 D 13 ...
Page 69: ...Index divider Section 2 N ...
Page 70: ......
Page 72: ...This page left intentionally blank ...
Page 129: ...Index divider Section 3 N ...
Page 130: ......
Page 187: ...Index divider Section 4 N ...
Page 188: ......
Page 190: ...TECHNICAL MANUAL A100K11209 v 1 3 Sound Reception System VSS V2 Installation User Manual ...
Page 204: ...15 VSS V2 Technical Manual A100K11209 v 1 3 4 7 Cable Connection Diagram ...
Page 206: ...17 VSS V2 Technical Manual A100K11209 v 1 3 5 2 VSS V2 Master Panel Dimensions in mm ...
Page 207: ...18 A100K11209 v 1 3 VSS V2 Technical Manual 5 3 VSS V2 Slave Panel Dimensions in mm ...