Removing the TPM
▶
Lay the system board on a soft, antistatic surface with its component side
facing down.
Figure 259: Removing the TPM screw
▶
Locate the slotted lower end of the TPM screw (1).
▶
Carefully loosen the TPM screw using a thin slotted screw driver (e.g.
watchmaker's screw driver) or the dedicated TPM screw driver (Japan) (2).
CAUTION
▶
Ensure to turn the screw
clockwise
in order to remove it.
▶
Slowly and carefully increase the pressure on the screw until it
begins to turn. The effort when loosing the screw should be as
low as possible.
Otherwise the thin metal bar may break, rendering it impossible
to loosen the screw.
▶
Remove the TPM screw (3).
▶
Remove the TPM on the upper side of the system board.
System board and components
356
Upgrade and Maintenance Manual
RX2530 M6