4.
Select the setting number by pressing the SET TEMP. or SET TEMP. button.
The setting number indicator flashes during setting number selection.
Example) Function number : 30, Setting number : 01
Setting number
5.
Confirm the setting by pressing the TIMER SET button.
The data will be transferred to the indoor unit.
Not good
Data is correctly set up on
the indoor unit.
● Data is not set up on the indoor unit
correctly (-- is displayed.)
● Set up the data again according to the
procedure in step 3, 4 above.
Good
Chapter 1-8. "Function details"
6.
Exit the function setting mode by pressing the 3 buttons of SET TEMP. , SET TEMP. , and
FAN at the same time for 5 seconds or longer.
After exiting the function setting mode, the display returns to the normal mode.
Normal mode display
If no button is pressed within 60 seconds after buttons mentioned above are pressed, it will au-
tomatically exit the function setting mode.
If you exit the function setting mode unintentionally during setting, enter the mode again ac-
cording to the procedure in step 2.
Setting up each indoor unit
Repeat the procedures from step 1 to 6, and set up the indoor units requiring function setting.
1-7. Indoor unit (setting by simple remote controller)
- (05-25) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Summary of Contents for AUXG18KVLA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 05 19 SR_CH01_SM001EG_02 ...
Page 22: ...3 4 Outdoor unit 01 16 3 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 23: ...2 TECHNICAL DATA AND PARTS LIST 2021 06 15 SR_CH02_SM001EG_04 ...
Page 69: ...3 TROUBLESHOOTING 2021 06 15 SR_CH03_SM001EG_03 ...
Page 72: ......
Page 143: ...4 CONTROL AND FUNCTIONS 2021 05 19 SR_CH04_SM001EG_02 ...
Page 146: ......
Page 185: ...5 FILED WORKING 2021 06 15 SR_CH05_SM001EG_03 ...