Local setting procedure
NOTE:
Before performing the function setting, be sure to stop the operation of the air conditioner.
Low noise mode
1.
Press the MODE switch button (S134) for 3 seconds or more to switch to “Local setting mode”.
2.
After confirming the LED lamp of POWER/MODE blinks 9 times, press the ENTER switch but-
ton (S132).
POWER
MODE
ERROR
(L1)
(L2)
(L3)
(L4)
(L5)
(L6)
PUMP
DOWN
LOW NOISE
PEAK CUT
Blinks
(9 times
)
Sign “
”: Lights off
3.
Press the SELECT switch button (S133), and adjust the LED lamp as shown below. Then the
LED lamp indicates the current setting.
(L2)
(L3)
LOW NOISE
Blink
LOW NOISE
MODE
4.
Press the ENTER switch button (S132).
(L2)
(L3)
LOW NOISE
LOW NOISE
MOD
E
Sign “ ”: Lights on
5.
Press the SELECT switch button (S133), and adjust the LED lamps as shown below.
PEAK CUT
MODE 1: Low
MODE 2: Lower
Blink
Blink
(L4)
(L5)
(L6)
6.
Press the ENTER switch button (S132) and fix it.
PEAK CUT
MODE 1: Low
MODE 2: Lower
(L4)
(L5)
(L6)
7.
To return to “Operating status display (Normal operation)”, press the EXIT switch button
(S131).
In case of missing how many times you pressed the SELECT and ENTER switch buttons:
1. To return to “Operation status display (Normal operation)”, press the EXIT switch button once.
2. Restart from the beginning of setting procedure.
NOTE:
In case of missing how many times you pressed the SELECT and ENTER switch buttons,
you must redo the setting procedure. Return to “Operation status display (Normal opera-
tion)” by pressing the EXIT switch button once, and restart from the beginning of the setting
procedure.
1-1. Outdoor unit
- (05-3) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Summary of Contents for AUXG18KVLA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 05 19 SR_CH01_SM001EG_02 ...
Page 22: ...3 4 Outdoor unit 01 16 3 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 23: ...2 TECHNICAL DATA AND PARTS LIST 2021 06 15 SR_CH02_SM001EG_04 ...
Page 69: ...3 TROUBLESHOOTING 2021 06 15 SR_CH03_SM001EG_03 ...
Page 72: ......
Page 143: ...4 CONTROL AND FUNCTIONS 2021 05 19 SR_CH04_SM001EG_02 ...
Page 146: ......
Page 185: ...5 FILED WORKING 2021 06 15 SR_CH05_SM001EG_03 ...