Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
– Model: AOHG36KRTA
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH
MED
LOW
QUIET
AUXG18KVLA
A zone
98
64
49
32
B zone
98
64
49
32
C zone
77
49
40
32
D zone
49
40
34
26
E zone
49
40
34
26
F zone
49
40
34
26
– Models: AOHG45KRTA and AOHG54KRTA
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH
MED
LOW
QUIET
AUXG18KVLA
A zone
95
66
51
33
B zone
95
66
51
33
C zone
80
51
41
33
D zone
51
41
35
27
E zone
51
41
35
27
F zone
51
41
35
27
AUXG22KVLA
AUXG24KVLA
A zone
95
66
51
33
B zone
95
66
51
33
C zone
80
51
41
33
D zone
56
41
35
27
E zone
56
41
35
27
F zone
56
41
35
27
1-1. Cooling operation
- (04-2) -
1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AUXG18KVLA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 05 19 SR_CH01_SM001EG_02 ...
Page 22: ...3 4 Outdoor unit 01 16 3 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 23: ...2 TECHNICAL DATA AND PARTS LIST 2021 06 15 SR_CH02_SM001EG_04 ...
Page 69: ...3 TROUBLESHOOTING 2021 06 15 SR_CH03_SM001EG_03 ...
Page 72: ......
Page 143: ...4 CONTROL AND FUNCTIONS 2021 05 19 SR_CH04_SM001EG_02 ...
Page 146: ......
Page 185: ...5 FILED WORKING 2021 06 15 SR_CH05_SM001EG_03 ...