6. OUTDOOR FAN CONTROL
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table 7 without relating to the compressor frequency.
( Table 7 : Outdoor fan speed after the defrost )
1. Fan Speed
1070rpm
01-07
( Fig.10 : Outside air temperature zone selection )
12°C
0°C
Outside air
temperature
Outside air
temperature
F zone
e
n
o
z
2
-
D
G zone
2°C
10°C
21°C
e
n
o
z
1
-
D
19°C
Cooling
Heating
D-2
D-1
F
Zone
1070/ 930/ 760/ 660/ 610/ 580/ 510/ 410
Refer to Fig. 10
(rpm)
200/ 180
G
200/ 170
Dry
840/ 820/ 740/ 660/ 620/ 450
740/ 620/ 450
200/ 180
200/ 170
840/ 820/ 500/ 450/ 410