3. Remove the Hex socket screw
and compressor terminal cover.
4. Remove the connectors.
[ R : White, S : Red, C : Black ]
Before servicing the unit, turnings of all power supplies.
Then, do not touch the electric parts for 10 minutes due to the risk of electric shock.
CAUTION
Cut the Discharge pipe in this range.
Cut the Suction pipe in this range.
・
Keep their shape better.
・
There is a possibility of catching fire to oil when removing by the welding without cutting it.
Remove the Compressor.
Range
Range
5. Remove the Compressor bolts. ( 3 places )
Tips!
Remove the Compressor bolts anticlockwise direction.
04-18