Type
Duct
Inverter heat pump
Model name
AMUG24LMAS
AMUG30LMAS
AMUG36LMAS
AMUG48LMAS
Connection pipe
Size
Liquid
in (mm)
Ø 3/8 (Ø 9.52)
Gas
Ø 5/8 (Ø 15.88)
Method
Flare
Flare
Flare
Flare
Drain port
Size
in (mm)
Ø 3/4 (19) [O.D.]
Ø 3/4 (19) [O.D.]
Ø 3/4 (19) [O.D.]
Ø 3/4 (19) [O.D.]
Operation range
Cooling
°F (°C)
64 to 90 (18 to 32)
%RH
80 or less
80 or less
—
—
Heating
°F (°C)
60 to 86 (16 to 30)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.67 °CDB/19.44 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/59 °FWB (21.11 °CDB/15 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.33 °CDB/6.11 °CWB).
– Pipe length: 24 ft 7 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
– Standard static pressure: 0.18 in.WG (45 Pa): 24 model, 0.23 in.WG (58 Pa): 30, and 36 model, 0.28 in.WG (70 Pa): 48 model
• Protective function might work when using it outside the operation range.
• *1: Maximum current:
–
The maximum value when operated within the operation range.
–
The total current of indoor unit and outdoor unit.
• *2: Sound pressure level:
–
Measured values in manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
1-1. Indoor unit
- (01-2) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Summary of Contents for AMUG24LMAS
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 07 15 SR_CH01_AR024EF_01 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2020 07 15 SR_CH02_AR024EF_01 ...
Page 47: ...3 TROUBLESHOOTING 2020 07 15 SR_CH03_AR024EF_01 ...
Page 105: ......
Page 106: ...4 CONTROL AND FUNCTIONS 2020 07 15 SR_CH04_AR024EF_01 ...
Page 146: ......
Page 147: ...5 FILED WORKING 2020 07 15 SR_CH05_AR024EF_01 ...