![Fujitsu AMUG24LMAS Service Manual Download Page 57](http://html.mh-extra.com/html/fujitsu/amug24lmas/amug24lmas_service-manual_118226057.webp)
Troubleshooting 4
External communication error
03-09
Detective actuators:
Detective details:
Forecast of cause :
OK
OK
External communication error
Check any loose or removed connection of between the controller PCB to the external I/OPCB
>>If there is an abnormal condition, correct it by refer to installation manual or
the technical manual.
Check the connection condtion on the external I/O PCB and the controller PCB
(If there is loose connector, open cable or mis-wiring)
the same signal has not been received
for 15 seconds
After receiving signal from external I/O PCB,
1. Connection failure
2. External I/O PCB failure
3. Controller PCB failure
Check Point 1 : Check connection
Indicate or Display:
Indoor unit
Operation lamp: 1 times Flash,
Timer lamp : 8 times Flash
Wired remote control
Error code : [E : 18]
Outdoor unit (AOUG36/48LMAS1)
Check Point 2: Replace external I/O PCB
If Check Point 1 do not improve the symptom, change external I/O PCB.
OK
OK
Check Point 3: Replace controller PCB
If Check Point 2 do not improve the symptom, change Controller PCB.
n: n times blinking
: Light ON
: Light OFF
Mode Error
2
5
A
B
F
E
D
C
15
Summary of Contents for AMUG24LMAS
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 07 15 SR_CH01_AR024EF_01 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2020 07 15 SR_CH02_AR024EF_01 ...
Page 47: ...3 TROUBLESHOOTING 2020 07 15 SR_CH03_AR024EF_01 ...
Page 105: ......
Page 106: ...4 CONTROL AND FUNCTIONS 2020 07 15 SR_CH04_AR024EF_01 ...
Page 146: ......
Page 147: ...5 FILED WORKING 2020 07 15 SR_CH05_AR024EF_01 ...