U41117-J-Z125-7-76
449
Explanation of console messages
Message lines
SXCH009
ESCON-adaptor <board> (ser_no <serial-nr) Compare Error in Channel <chn>
ALERT
Meaning
A test of the internal data paths on the ESCON board (PCEAS/PCEAT) which runs during
the startup phase and idle times returned an error.
Response
Replace the ESCON board.
SXCH010
ESCON-adaptor <board> CRC READ Error in Channel <chn>
ALERT
Meaning
During a read access the data was corrupted when it was transferred from the SINIX me-
mory to the ESCON channel.
Response
Replace the ESCON board.
SXCH011
ESCON-adaptor <board> CRC WRITE Error in Channel <chn>
ALERT
Meaning
During a write access the data was corrupted when it was transferred from the ESCON
channel to the SINIX memory.
Response
Replace the ESCON board.
9.2.3
SXCM... (CHIM)
SXCM001
chim1 (sadm9): SCSI-Bus reset
None
This message is part of a message complex (see the
section “Bus Reset for SCSI
Controller” on page 542
).
Summary of Contents for CentricStor V3.1D
Page 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Page 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Page 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Page 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Page 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...