U41117-J-Z125-7-76
77
Selected system administrator activities
Reorganization
Only physical volumes in
read
status on which the relative proportion of valid data is less
than the percentage value configured in the
Fill Grade
parameter are taken into account. If
a physical volume is in
write
status and the percentage value for its valid data drops below
the
Fill Grade
value, it is placed in
read
status and is therefore a candidate for reorganization.
The costs are estimated according to the following formula:
( N * estimate1 ) + ( M / estimate2 )
where
N
Number of valid logical volumes on the physical volume
estimate1
Estimated overhead, in seconds, for each logical volume which is to be writ-
ten (configuration parameter
Write Overhead
)
M
Sum, in MiB, of the data contained on the valid logical volumes
estimate2
Estimated write performance in MiB/sec (configuration parameter
Write
Throughput
)
When the two estimated values are configured, it must be borne in mind that these do not
depend solely on the hardware characteristics of the tape drives, but also to a large degree
on the relative size of the valid logical volumes. For example, large logical volumes have
fairly certainly been displaced from the TVC and would have to be read in first, which practi-
cally doubles the time required and halves the write performance.
Example
pos PV TL PVG state next-bl LVs - val cap/GB valid/GB valid %
:
15 CSJ016 JAGUAR JAG001 _r__ 2518971 1156 583 279.397 0.000 0
16 CSJ017 JAGUAR JAG001 _r__ 1109297 16 1 279.397 15.795 5
:
The default values (
Write Overhead
= 3,
Write Throughput
= 5) result in the following costs:
CSJ016 is therefore selected.
Example with
Write Overhead
= 3 and
Write Throughput
= 20:
CSJ017 is therefore selected.
PV
Number of valid LVs
Valid data volume (MiB)
Estimated costs
CSJ016
583
0
1749
CSJ017
1
16155
3234
PV
Number of valid LVs
Valid data volume (MiB)
Estimated costs
CSJ016
583
0
1749
CSJ017
1
16155
810
Summary of Contents for CentricStor V3.1D
Page 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Page 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Page 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Page 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Page 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...