500
U41117-J-Z125-7-76
Message lines
Explanation of console messages
SXSM018
sma#: Fan <Id>: Fan is not manageable
ALERT
Meaning
Fan
<Id>
has failed and must be replaced.
If the fan is inoperable for more than 3 minutes, the SINIX system is shut down and the
server deactivated to prevent the server from overheating.
Response
Notify maintenance staff.
SXSM019
sma#: Fan <Id>: Removable fan is not installed
ALERT
Meaning
Fan
<Id>
is not installed or has failed.
If the fan is inoperable for more than 3 minutes, the SINIX system is shut down and the
server deactivated to prevent the server from overheating.
Response
Notify maintenance staff.
SXSM021
sma#: Power Supply <Id> AC fail occurred
ALERT
Meaning
Power supply module
<Id>
is either not installed or not connected or defective.
Response
Notify maintenance staff.
SXSM022
sma#: Power Supply <Id> DC fail occurred
ALERT
Meaning
Power supply module
<Id>
has failed.
Response
Notify maintenance staff.
SXSM024
sma#: Power Supply <Id> is not manageable.
ALERT
Meaning
Power supply module
<Id>
has failed.
Response
Notify maintenance staff.
Summary of Contents for CentricStor V3.1D
Page 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Page 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Page 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Page 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Page 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...