Glossary
Distribute and Activate
➟
DNA
Distributed Tape Volume File System
➟
DTVFS
DNA
The
Distribute and Activate
(DNA) function must be invoked in
GXCC
every time a
change is made to the configuration of the CentricStor system. This ensures that the
new configuration is distributed to and activated on all the
ISP
s.
➟
section “Distribute and Activate” on page 188
DTVFS
DTVFS (Distributed Tape Volume File System) is a file system implementation which
was developed specially for CentricStor which has been adapted to the requirements of
high concurrence and of high-speed data traffic both between the
TVC
(Tape Volume
Cache) and hosts and between the
TVC
and tape drives. In CentricStor V3.1D, all Tape
File Systems (
TFS
s) of the
TVC
are of the type
dtvfs
.
Emulation
An emulation is a functional simulation of one system by another. The emulated system
receives the same data, executes the same programs and achieves the same results
as the original system.
Example:
A logical drive (
LD
) emulates a physical drive (
PD
).
Extented Tape Control Center
➟
XTCC
Failover
➟
AutoVLP failover function
FC
Fibre Channel (FC) is a standard which was designed for serial and continuous high-
speed transfer of large volumes of data. It is also used in the
Storage Area Network
(
SAN
)
within CentricStor and in some cases for the connections between the
ICP
s and the
hosts and between the
IDP
s and the back-end devices. The FC controllers used in
CentricStor support bandwidths of between 1 Gb/s (Gigabit per second) and 4 Gb/s.
In the case of a Fibre Channel, each device has a WWNN (World Wide Node Name)
and each port of a device a WWPN (World Wide Port Name) as a unique worldwide
identifier. Each of these is a 64-bit address which is generally presented in hexadecimal
format as 8 bytes separated by colons.
A distinction is made between three types of Fibre Channel topologies :
–
Switched Fabric (FC-SW)
In the case of the
Fibre Channel Switched Fabric
, point-to-point connections are
switched between the channel via one or more FC switches.
–
Arbitrated Loop ( FC-AL)
In the case of the
Fibre Channel Arbitrated Loop
a logical bus is involved on which all
terminals share the same bandwidth. In CentricStor, FC-AL can only be used to
connect back-end devices.
–
Point-to-Point (FC-P2P)
This refers to a direct connection between two terminals.
Summary of Contents for CentricStor V3.1D
Page 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Page 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Page 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Page 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Page 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...