Page 38
5.
Use left sheath clamp, set the 250µm UV coating fiber into V-grooves. Note – Cleave length:
16mm.
6.
Drive fiber past electrode using the ZL motor manually. Note – Don’t overrun ZL-Motor.
7.
Record values (ZL-XL), (ZL-XR), (ZL-YL), (ZL-YR). Refer to Fig. 4.10.2.
8.
Use right sheath clamp, set the 250µm UV coating fiber into V-grooves. Note – Cleave length:
16mm.
9.
Drive fiber past electrode using the ZR motor manually. Note – Don’t overrun ZR-Motor.
10.
Record values (ZR-XL), (ZR-XR), (ZR-YL), (ZR-YR). Refer to Fig. 4.10.2.
ZL-XR
ZL motor moving
Camera Position
X
Y
176.9
198.7
219.3
257.5
277.9
300.1
177.0
198.8
219.4
258.0
278.4
300.6
ZL
Camera Position
X
Y
176.9
198.7
219.3
257.5
277.9
300.1
177.0
198.8
219.4
258.0
278.4
300.6
ZR
ZR motor moving
ZL-XL
ZR-YL
ZR-YR
You calculate shown below.
1)
A = (ZL-XL) – (ZL-XR) on ZL fiber
2)
B = (ZL-YL) – (ZL-YR) on ZL fiber
3)
C = (ZR-XL) – (ZR-XR) on ZR fiber
4)
D = (ZR-YL) – (ZR-YR) on ZR fiber
ZR-XL
ZL-YL
ZL-YR
ZR-XR
Fig. 4.10.2
11.
Calculate A, B, C and D from formula in Fig. 4.10.2.
12.
Confirm the difference (A-C) and (B-D) are less than 1.5 line.
ZL
ZR
Difference
Standard
X
A
C
(A-C)
(A-C)<= 1.5 line
Y
B
D
(B-D)
(B-D)<= 1.5line