Page 8
CAUTION
Do not store the equipment in any area where extreme heat and humidity are present. It may cause
equipment damage.
During / after heating the splice protector, do not touch the ceramic heater and the splice protector.
The high temperature may cause personal injury.
Do not place the splicer at an unstable place. In a case of dropping the equipment, it can cause
personal injury or equipment damage.
Precise adjustment and alignment have been made to this splicer. Do not give a strong shock. Use a
carrying case to transport and store the splicer. The carrying case will prevent damage and provide
protection from moisture, vibration and shock during storage and transportation.
Keep the splicer free from sand or dust. It degrades the splicing performance.
Replace the electrodes properly.
• Only specified electrodes can be used.
• Set the new electrodes to the correct position.
• Replace the electrodes as a pair.
Not following the above cautions can cause abnormal discharge. And, it can result in equipment
damage or degrading the splicing quality.
Do not use any other chemical except alcohol to clean the objective lens, V-groove, mirror, LCD
monitor, body and so on. Doing so may cause blurring, discoloration or deterioration.
The splicer requires no lubrication. Oil may degrade the performance and damage the splicer.
Repair or re-adjustment should be performed by an authorized engineer, except the electrodes
replacement. Failure to repair the equipment can result in personal injury or equipment damage.
Please contact a sales agency in your country.