Page 47
§ 4.18.
Tube Heater Adjustment
§ 4.18.1.
Adjust Tube Heater Temperature
1.
Prepare the temperature sensor for the heater adjustment.
•
Method 1 -
Thermo spot sensor (non-touch sensor).
Refer to Fig. 4.18.1 and Fig. 4.18.2. Set the thermo spot sensor on the splicer.
Thermo spot sensor
*
Tool for fixing the thermo spot sensor.
Note: This unit can only use for 40S.
Splicer
Set the tool for fixing the thermo spot sensor on the corner
Thermo spot sensor
*
(display part)
Fig. 4.18.1
Push
Pus
h
Push the tool for fixing the thermo
spot sensor on the corner
Base frame
The tool for fixing the thermo spot sensor
Fig. 4.18.2