2.1 Specifications
2-1
1
2
3
4
5
6
7
8
9
10
2.1
Specifications
2.1.1 General Specifications
*1 Use the unit in an environment where the wet-bulb temperature is 39
C or less; otherwise the unit may be damaged.
*2 This indicates the distribution section to which the unit is intended to be connected to within the path between the distribution of the public power
network and machinery in the facility.
“Category II” applies to devices supplied with power from mains sockets or similar points. The withstand surge voltage is 500 V for devices rated up to
50 V.
*3 This is an index that expresses the degree of conductive pollution in the environment where the unit is used. “Pollution degree 2” indicates the
condition where only non-conductive pollution occurs. However, due to condensation, temporary conductive pollution may occur.
Item
X1121iSD
X1121iSRD
X1151iSD
X1151iSRD
Conformance
Standards
CE Marking
EMC directive (2014/30/EU) EN61000-6-2, EN61000-6-4
RE directive (2014/53/EU) EN300 328, EN301 893, EN301 489-1, EN301 489-17, EN62311
RoHS directive
UL/cUL
UL61010-1, UL61010-2-201 (E313548)
CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201
KC
Conforming
UKCA
Conforming Hardware version b or later.
Radio Law
Non-conforming
Japan: MIC
USA: FCC
Canada: ISED
Europe: RED
South Korea: KC
Taiwan: NCC
Non-conforming
Japan: MIC
USA: FCC
Canada: ISED
Europe: RED
South Korea: KC
Taiwan: NCC
Power Supply
Permissible Voltage Range
24 VDC
10 %
Permissible Momentary Power
Failure
Within 1 ms
Power Consumption (Maximum
Rating)
41 W or less
51 W or less
Rush Current
24 A or less, 6 ms (ambient temperature at 25
C)
Withstand Voltage
DC external terminals to FG: 500 VAC for 1 minute
Insulation Resistance
DC external terminals to FG: 500 VDC, 10 M
or higher
Physical
Environment
Operational Ambient Temperature 0
C to +45
C
*1
Storage Ambient Temperature
10
C to +60
C
*1
Operational Ambient Humidity
85 % RH or less (without dew condensation)
*1
Storage Ambient Humidity
85 % RH or less (without dew condensation)
*1
Altitude
2000 m or less
Atmosphere
No corrosive gas, no excessive dust, and no conductive dust
Overvoltage Category
*2
Category II
Pollution degree
*3
2
Mechanical
Working
Conditions
Vibration Resistance
JIS B 3502 (IEC61131-2) compliant
Vibration frequency: 5 to 9 Hz Half-amplitude: 3.5 mm,
Vibration frequency: 9 to 150 Hz Constant acceleration: 9.8 m/s
2
(1 G), 3 directions of X, Y, and Z:
10 times each
Shock Resistance
JIS B 3502 (IEC61131-2) compliant
Peak acceleration: 147 m/s
2
(15 G), 3 directions of X, Y, and Z: 3 times each (18 times in total)
Electrical Working
Conditions
Noise Resistance
Noise voltage: 1000 Vp-p, Pulse width: 1
s, Rising time: 1 ns
(Measured using a noise simulator)
Static Electricity Discharge
Resistance
Compliant with IEC61000-4-2, Contact: 6 kV, Air: 8 kV
Installation
Specifications
Grounding
100
or less, FG/SG connected
Protective
Structure
*4
Panel Front
Surface
Equivalent to IP66 (when waterproof gasket is installed)
Rear Case
Equivalent to IP20
Cooling System
Natural cooling
Mounting Method
Fitted into a mounting panel
Mounting Panel Thickness
1.5 to 4.0 mm
*5
Weight
Approx. 3.2 kg
Approx. 3.9 kg
Dimensions
External (W
H
D)
320.0
241.0
66.7 mm
406.0
271.0
68.2 mm
Panel cut-out (W
H)
309.0
230.0
mm
395.0
260.0
mm
Case
Color
Black
Material
Front: PBT+GF30 resin
Rear: Sheet metal
+0.5
0
+0.5
0
+0.5
0
+0.5
0
Summary of Contents for MONITOUCH X1 Series
Page 1: ...Series Hardware Specifications...
Page 3: ......
Page 5: ......
Page 9: ......
Page 13: ......
Page 14: ...1 Product Outline 1 1 Features 1 2 Models and Peripheral Equipment 1 3 System Configuration...
Page 15: ......
Page 19: ...1 Product Outline 1 4...
Page 21: ......
Page 40: ...3 Installation 3 1 Installation 3 2 Power Supply 3 3 Securing USB and HDMI Cables 3 4 Battery...
Page 41: ......
Page 51: ...3 Installation 3 10...
Page 53: ......
Page 59: ......
Page 162: ...6 Errors 6 1 Errors 6 2 Troubleshooting...
Page 163: ......
Page 173: ...6 Errors 6 10...
Page 174: ...7 Inspection and Maintenance 7 1 Inspection and Maintenance 7 2 Warranty Policy...
Page 175: ......
Page 179: ...7 Inspection and Maintenance 7 4...