1
Preface
Thank you for purchasing our DeviceNet Interface Option OPC-E1-DEV.
Mounting this option on your FRENIC-Multi allows you to connect the FRENIC-Multi to a DeviceNet master unit
(e.g., PC and PLC) and control it as a slave unit using the run command, speed command, and access to
function codes.
This option has the following features:
• Data Rate (baud rate): 125 kbps, 250 kbps, 500 kbps
• I/O Message:
Polling and Change of State supported
• Applicable Profile:
AC Drive profile
• Reading and writing all the function codes applicable to the FRENIC-Multi (User Defined Assembly I/O or
Explicit Message)
This product has been tested by ODVA authorized Independent Test Lab and found to comply with ODVA’s
DeviceNet Conformance Test Version 18.
Certification Logo Mark:
DeviceNet
is a trademark of Open DeviceNet Vendor Association, Inc. (ODVA).
This instruction manual does not contain inverter handling instructions.
Read through this instruction manual in
conjunction with the FRENIC-Multi Instruction Manual (INR-SI47-1094-E) and be familiar with proper handling
and operation of this product. Improper handling might result in incorrect operation, a short life, or even a failure
of this product.
Keep this manual in a safe place.
Related Publications
Listed below are the other materials related to the use of the DeviceNet interface option "OPC-E1-DEV." Read
them in conjunction with this manual as necessary.
• RS-485 Communication User's Manual
(MEH448)
• FRENIC-Multi Instruction Manual
(INR-SI47-1094-E)
The materials are subject to change without notice. Be sure to obtain the latest editions for use.
Safety precautions
Read this manual thoroughly before proceeding with installation, connections (wiring), operation, or
maintenance and inspection. Ensure you have sound knowledge of the device and familiarize yourself with all
safety information and precautions before proceeding to operate the inverter.
Safety precautions are classified into the following two categories in this manual.
Failure to heed the information indicated by this symbol may lead to
dangerous conditions, possibly resulting in death or serious bodily
injuries.
Failure to heed the information indicated by this symbol may lead to
dangerous conditions, possibly resulting in minor or light bodily injuries
and/or substantial property damage.
Failure to heed the information contained under the CAUTION title can also result in serious consequences.
These safety precautions are of utmost importance and must be observed at all times.