19
Chapter 7 I/O MESSAGE
7.1 Overview
I/O Message is a communication process that cyclically transfers data between the DeviceNet master and
slave.
This option supports two types of I/O Message connections--Poll and Change-of-State connections. It also
supports four types of I/O assembly instances as data formats in I/O Message, as listed in Table 7.1. One of the
four instances can be selected for input and output each.
The I/O assembly instances should be specified using inverter's function codes o31 and o32.
- Poll connections allow the master to periodically poll the slave for data. In response to the
request, the slave sends data. In Change-of-State connections, the slave sends data only
when the data has changed.
- Input and output assembly instances should not be necessarily set to the same instance type.
(Ex. Output assembly instance = Extended speed control output, Input assembly instance =
User defined assembly input.)
Table 7.1 Configuring I/O Assembly Instances
o31, o32
Type
Instance ID
Description
Length
(words)
o31=20
20
Basic Speed Control Output
2
o31=0 or 21
21
Extended Speed Control Output
(Factory default)
2
o31=100
100
Fuji Drive Assembly Output
2
o31=102
Output
(from master
to slave)
102
User Defined Assembly Output
4
o32=70
70
Basic Speed Control Input
2
o32=0 or 71
71
Extended Speed Control Input
(Factory default)
2
o32=101
101
Fuji Drive Assembly Input
2
o32=103
Input
(from slave
to master)
103
User Defined Assembly Input
4