27
(4) User Defined Assembly Instance
Output (from master to this option): o31=102
word
bit15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
bit0
0
User-defined function code 1 (write) (data of function code specified by o40)
1
User-defined function code 2 (write) (data of function code specified by o41)
2
User-defined function code 3 (write) (data of function code specified by o42)
3
User-defined function code 4 (write) (data of function code specified by o43)
Input (from this option to master): o32=103
word
bit15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
bit0
0
User-defined function code 1 (read) (data of function code specified by o48)
1
User-defined function code 2 (read) (data of function code specified by o49)
2
User-defined function code 3 (read) (data of function code specified by o50)
3
User-defined function code 4 (read) (data of function code specified by o51)
Summary of Contents for FRENIC-Multi OPC-E1-DEV