2-2
DANGER
All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished
with the appliance. Refer to the wiring diagram(s) furnished with the appliance when installing or servicing
this equipment.
DANGER
Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause
injury. The appliance area must be kept free and clear of combustible material at all times.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF.
Do not attempt to start the fryer(s) until power is restored.
This appliance must be kept free and clear of combustible material, except that it may be installed on combustible
floors.
2.1.1 Clearance
and
Ventilation
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A
minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.
WARNING
Do not block the area around the base or under the fryers.
DANGER
No structural material on the fryer should be altered or removed to accommodate placement of the fryer
under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
2.1.2
Electrical Grounding Requirements
All electrically operated appliances must be grounded in accordance with all applicable national and local codes,
and, where applicable, CE codes. In the absence of local codes, the appliance must be grounded in accordance with
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. All units (cord
connected or permanently connected) should be connected to a grounded power supply
system. Wiring diagrams are supplied with the fryer. Refer to the rating plate on the inside of
the fryer door for proper voltages.
The equipotential grounding lug allows all the equipment in the same location to be electrically
connected to ensure there is no electrical potential difference between the units, which could be
hazardous.
DANGER
This appliance is equipped with a special (grounding) plug for your protection against electrical shock, and
must be plugged directly into a properly grounded receptacle. Do not cut, remove, or otherwise bypass the
grounding prong on this plug!
WARNING
To ensure the safe and efficient operation of the fryer and hood, the electrical plug for the control power,
which powers the hood, must be fully engaged and locked in its pin and sleeve socket.
2.1.3 Australian
Requirements
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory
regulations.