-----
An invalid welding process was called up on the robot interface (no. 37) or
an empty flag was selected (no. 32)
Call up a valid welding process or select assigned "Save" button
Cause:
Remedy:
ELn | 8
The connected wire-feed unit is not supported
Connect supported wire-feed unit
Cause:
Remedy:
ELn | 12
Different control panels for selecting materials are in the system
Connect similar control panels to select materials
Cause:
Remedy:
ELn | 13
Invalid change of welding process during welding
During welding do not carry out any illegal change of the welding process,
reset error message by pressing any button
Cause:
Remedy:
ELn | 14
More than only one robot interface is connected
Only one robot interface may be connected, check the system configuration
Cause:
Remedy:
ELn | 15
More than only one remote control unit is connected
Only one remote control unit may be connected, check the system configur-
ation
Cause:
Remedy:
Err | IP
The power source control has detected a primary overvoltage
Check the mains voltage.
If the service code is still present, turn off the power source, wait 10
seconds, and then turn on the power source.
If the fault persists, contact After-Sales Service
Cause:
Remedy:
Err | PE
The earth current watchdog has triggered the safety cut-out of the power
source.
Switch off the power source
Place the power source on an insulating surface
Connect the grounding (earthing) cable to a section of the workpiece that is
closer to the arc
Wait for 10 seconds and then switch the power source on again
If you have tried this several times and the error keeps recurring, contact
After-Sales Service
Cause:
Remedy:
Err | Ur
If the VRD option is available, the open circuit voltage limit of 35 V has been
exceeded.
Switch off power source
Wait for 10 seconds and then switch the power source on again
Cause:
Remedy:
99
EN
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...