Setup parameters
for MIG/MAG
standard manual
welding
"Min." and "max." are used for setting ranges that differ according to power source, weld-
ing program, etc.
GPr
Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
GPo
Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
Fdi
Feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
bbc
Burn-back time correction
Burn-back time effect due to a delayed switch-off of the welding current after the
wire electrode stops being fed forward. A ball forms on the wire electrode.
Unit: s
Setting range: AUt, 0 - 0.3
Factory setting: AUt
IGC
Ignition current
Unit: A
Setting range: 100 - 650
Factory setting: 500
Ito
Length of wire that is fed before the safety cut-out trips
Unit: mm (in.)
Setting range: OFF, 5 - 100 (OFF, 0.2 - 3.94)
Factory setting: OFF
NOTE!
The Ito function (wire length up to safety cut-out) is a safety function.
The length of wire that is fed before the safety cut-out trips may differ from the pre-set
wire length, particularly when the wire is being fed at fast wire speeds.
SPt
Spot welding time / interval welding time
Unit: s
Setting range: 0.3 - 5
Factory setting: 0.3
SPb
Interval pause time
Unit: s
Setting range: OFF, 0.3 - 10 (in 0.1 s increments)
Factory setting: OFF
Int
Interval
Displayed only if a value has been set for SPb
Unit: -
Setting range: 2T (2-step), 4T (4-step)
82
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...