Generator-powered operation
Generator-
powered opera-
tion
The power source is generator-compatible.
The maximum apparent power S
1max
of the power source must be known in order to
select the correct generator output.
The maximum apparent power S
1max
of the power source is calculated as follows:
3-phase devices:
S
1max
= I
1max
x U
1
x √3
Single-phase devices: S
1max
= I
1max
x U
1
See device rating plate or technical data for I
1max
and U
1
values
The generator apparent power S
GEN
needed is calculated using the following rule of
thumb:
S
GEN
= S
1max
x 1.35
A smaller generator may be used when not welding at full power.
IMPORTANT!
The generator apparent power S
GEN
must always be higher than the max-
imum apparent power S
1max
of the power source.
When using single-phase devices with a 3-phase generator, note that the specified gen-
erator apparent power is often only available as a whole across all three phases of the
generator. If necessary, obtain further information on the single-phase power of the gen-
erator from the generator manufacturer.
NOTE!
The voltage delivered by the generator must never exceed the upper or lower lim-
its of the mains voltage tolerance range.
Details of the mains voltage tolerance can be found in the "Technical data" section.
48
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...