Factory setting: 10 (393.7)
bbc
burn-back time correction -
Burn back effect due to wire withdrawal at end of welding
Unit: s
Setting range: Aut, 0 - 0.3
Factory setting: Aut
Ito
Ignition time-out function - Length of wire that is fed before the safety cut-
out is triggered
Unit: mm (in.)
Setting range: Off, 5 - 100 (Off, 0.2 - 3.94)
Factory setting: OFF
NOTE!
The "Ignition time-out" function (ito) is a safety function.
The length of wire that is fed before the safety cut-out trips may differ from the preset
wire length, particularly when the wire is being fed at fast wire feed speeds.
The "Ignition time-out" function (ito) is explained in the "Special functions and options"
section.
SPt
Spot time - spot / stitch welding time
Unit: s
Setting range: OFF, 0.1 - 5
Factory setting: OFF
SPb
Spot break - stitch pause time
Unit: s
Setting range: OFF, 0.1 - 10 (in 0.1 s increments)
Factory setting: OFF
FAC
Factory - reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset.
IMPORTANT!
When the power source is reset, all personal settings in the Setup
menu are lost.
When the power source is reset, operating points that were saved using the
"Save" buttons are not deleted, but are retained in the memory. The functions in
the second level of the Setup menu (2nd) are also not deleted. Exception: Igni-
tion time-out function parameter (ito).
2nd
Second level of the Setup menu (see "Setup menu - level 2")
Setup parameters
for MMA welding
IMPORTANT!
If you reset the power source using the FAC factory setup parameter, the
hot-current time (Hti) and HotStart current (HCU) setup parameters are also reset.
HCU
HotStart current
Unit: %
Setting range: 100 - 200
84
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...